Lokruok ma ling i gwoko leng pa pii: Pirango ma Sensors ma timo ngo reagent ubedo piny manyen ma jutiyo kudu i tic?
Calu cik mi gwoko pii i ng'om zoo ubemedere (e.g., EU's Water Framework Directive, US EPA's Clean Water Act), ju ma timo tic man judongo mi adhura gibe nwangu peko madit mi lubo tok pii pio pio, maber man maber. LUMINSENS's manyen Namba mi sensor dwoko wang lembe eni ni rwom ma malu ku yub maber pa kwo pa piny—dwoko piny ma copo timere pi pii ma cido man gwoko kwo pa piny.
Pimo ber pa pii 101: Pirango ma COD, TOC & BOD pire tek (pi tic moko ci)
Pi piny moko ci ma tiyo ku pii (kabedo, factory, ju ma gwoko kwo pa piny), lembe adek ma juporo ngo—eni the lembe ma nyayu adwogi marac ikum tic man lubu cik:
COD (Chemical Oxygen Demand):
Pimu oxygen ma mitere pi turu piny ma rac ma kwo/ma kwo ngo. Mi lanyuth:
- Kabedo mi cam man kongo: COD ma malu in pii ma cido nyutho nya pii ma cido (e.g., cam madong)--ka judwoko piny eca nyayu cul nyo jwigo twero mi wodhu pii.
- Factory mi kemikol: COD ma malu nyutho piny ma rac ma podi juyubu ngo, ma copo nyayu two i pii ma piny ka juwodho gi woko.
TOC (Total Organic Carbon):
Kwan wel pa piny ma kwo (ma uketho i iye piny ma copo nyothre ngo). Ber pi yen ma pii madhu: kadi TOC ma nok de ecopu timo tic ku yath ma jwigo two (macalu chlorine) mi yubu piny ma rac.
BOD (Biochemical Oxygen Demand):
Lubo oxygen ma microbes camu ma nyayu piny ma kwo. BOD ma malo in kulo/nam nyayu kwo ma kwo i pii-ma weko ebedo piny ma pire tek pi pimo adwogi pa kwo pa piny.
Peko ma ungwe i tic: Peko mi lubo tok lembe macon
Pi oro madwong, kabedo mapol ubedu ka tiyo ku reagent-based lab testing—ento yore eni bino ku peko mapol:
- Bei ma lee man ma rac: Reagents (ma pol kare gi rac) mitu juketh i friji, juketh igi kare ku kare, man juwodh gi woko (bei $1000+/dwi pi yen madongo).
- Paru ma ukadhu: Adwogi mi lab tero sawa 24-48. Ka COD pa pii ma cido i factory umedire nyathotho, jurutic copo ngo ni loko yore mi yiku pii i kare ma mitire—ma copo ketho gi timo ngo lembe ma rac.
- Gwoko ma tek: Lubu 5+ metrics (COD, TOC, turbidity) mito sensors mapol matung tung, acel acel mito calibration man cleaning (ma tero sawa 2-3/yenga pi jam tic acel acel).
- Chloride interference: Yore ma jutiyo kudu ku reagent pol kare nyayu COD in pii ma chloride dwong i iye (e.g., kabedo mi pii ma cido i dhu nam)—ma kelo alarm mi ndra nyo lembe ma rwinyo.
LUMINSENS COD Sensor: Daru peko, acel acel
Jam tic acel eni kwanyu peko macon man medo tic:
- Yub ma epe ku reagent: Dwoko $12,000+/mwaka i wel pa reagent man jwigo piny ma rac (ma rwate ku yub mi gwoko kwo pa ng'om zoo calu SDG 6: Pi maleng).
- Nwangu piny ceke i acel: Lubu COD, TOC, BOD, turbidity man temperature—loko 3+ sensors, dwoko piny sawa mi gwoko piny ku 70%.
- Adwogi mi kare mandha: Cwalu lembe i 30-60 seconds, kara jurutic gi lok yore mi yath ndhundhu (ku jwigo cul).
- Brush ma yweyu kende: Gengo pii ma nyai—medu kare mi gwoko piny nicaku i yenga acel nitundo i dwi acel.
- Anti-chloride accuracy:
Global-Fit Specs pi lembe moko ci
Yer kit ma rwate ku yeny peri:
| Lanyuth | COD Range | TOC Range | BOD Range | Turbidity Range |
|---|---|---|---|---|
| LMS-COD100H | 0.1–1500mg/L | 0.1–750 mg/L | 0.1–900mg/L | 0.1–4000 NTU |
| LMS-COD100L | 0.1–500mg/L | 0.1–200mg/L | 0.1–300 mg/L | 0.1–1000 NTU |
Juyike ku 316L stainless steel (32mm×200mm) man eromo ku RS485 Modbus, eromo ku SCADA systems—ber pi pii ma rac mi adhura, ka yubu bongo, nyo ka gwoko kwo pa piny i ng'om zoo.
Medu rwom pa pii peri (man jwigo wic)
Kadi bed ni ibedo jatel wi kabedo mi pii ma cido ma ool ku bey pa reagent, nyo itiye jaradiru mi gwoko kwo ma mitu lembe ma wok i saa mandha, LUMINSENS COD Sensor loko gwoko leng pa pii kud i tic ma tek ni bedo piny maber.
Lembe mi rwate
Email: luminsens@luminsens.com
Kabedo mir Internet:https://www.luminsens-sensor.com/
Pi lembe matung tung nyo penji mi dikiri mi ng'om zoo, wec ku juwil mwa tin.
















